TR-TC-2A/L0107-2A - Micro Flow Rate Syringe Pump


COMPANY : Tryte Technology (H.K.) Limited
ADD : UNIT 04, 7/F, BRIGHT WAY TOWER, NO. 33 MONG KOK ROAD, KOWLOON, HONGKONG.
TEL:00852-2389298
FAX: 00852-35902333
CELL:0086-15367067787(Robin)
SITE : www.trytetc.com
SKYPE : live:myformat666
EMAIL : sale@trytetc.com
more>>>

  • Name: TR-TC-2A/L0107-2A - Micro Flow Rate Syringe Pump
  • Model : TR-TC-2A
  • Erp code: 9000000391
  • | Share

TR-TC-2A.png

Instruction:

TR-TJ-2A/L0107-2A is a single-channel micro syringe pump which has infusion/withdrawal mode. It combines precision, compact size with ease of installation and operation. It can hold µL unit standard glass syringe. The features of accurate distance control and broad linear speed range (7.94 µm/min - 79.4 mm/min) can meet versatile requirements. Its vertical (horizontal) installation structure makes this pump easily used in micromanipulator, stereotaxic instrument for various biologic research applications.

 

Specification:

- Max. infusion distance: 70 mm 
- Acceptable glass syringe : 5 µL - 1000 µL 
- Linear speed: 7.94 µm/min - 79.4 mm/min 
- Adjusting resolution: 7.94 µm/min 
- Distance resolution: 0.165 µm 
- Linear force: >20 N 
- Setting mode: Membrane keypad and rotary encoded switch 
- Accuracy: < +/- 0.5% error in the condition of > 30% of max. infusion distance 
- Display: 128 x 64 graphic LCD 
- External control: Start/Stop control, fast forward control, fast reverse control 
- Communication interface: RS 485 
- Power supply: AC 100 - 240V or DC 12 V 
- Power consumption: < =10 W 
- Operating condition: Temperature 0 - 40 °C ; relative humidity < 80 % 
- Controller dimensions (L x W x H): 170 x 108 x 65 (mm) 
- Controller weight: 0.5 Kg 
- Drive Unit dimensions (L x W x H): 180 x 46 x 78 (mm) 
- Drive Unit weight: 0.6 Kg 
- IP rating: IP 21

 

Functions and features:

- Working mode: Infusion, withdrawal, infusion/withdrawal, withdrawal/infusion, continuous 
- User-defined glass Syringe: Save 4 inner diameters of user-defined glass syringe barrel 
- Linear force output: Full stroke > 20 N 
- Memory functon: Select resume operaton or remain stopped when power returns after an interruption 
- Signal output: Start/Stop output, cw/ccw output (Open Collector) 
- Calibration: Acquire accurate volume through calibration 
- Fast forward & fast reverse: Infusion or filling at the max. Speed

 

Parameters:

Controller
(Product code)

Drive Unit
(Product Code)

Syringe (μl)

Syringe ID (mm)

Flow Rate (nl/min-μl/min)

TR-TC-2A (0503111)

L0701-2A (0503011)

5

0.35

0.764 - 7.64

10

0.50

1.559 - 15.59

25

0.80

3.991 - 39.91

50

1.10

7.546 - 75.46

100

1.60

15.96 - 159.6

250

2.30

32.99 - 329.9

500

3.25

65.87 - 658.7

1000

4.61

132.5 - 1325

 

 


Specification:

- Max. infusion distance: 70 mm 
- Acceptable glass syringe : 5 µL - 1000 µL 
- Linear speed: 7.94 µm/min - 79.4 mm/min 
- Adjusting resolution: 7.94 µm/min 
- Distance resolution: 0.165 µm 
- Linear force: >20 N 
- Setting mode: Membrane keypad and rotary encoded switch 
- Accuracy: < +/- 0.5% error in the condition of > 30% of max. infusion distance 
- Display: 128 x 64 graphic LCD 
- External control: Start/Stop control, fast forward control, fast reverse control 
- Communication interface: RS 485 
- Power supply: AC 100 - 240V or DC 12 V 
- Power consumption: < =10 W 
- Operating condition: Temperature 0 - 40 °C ; relative humidity < 80 % 
- Controller dimensions (L x W x H): 170 x 108 x 65 (mm) 
- Controller weight: 0.5 Kg 
- Drive Unit dimensions (L x W x H): 180 x 46 x 78 (mm) 
- Drive Unit weight: 0.6 Kg 
- IP rating: IP 21

 

Functions and features:

- Working mode: Infusion, withdrawal, infusion/withdrawal, withdrawal/infusion, continuous 
- User-defined glass Syringe: Save 4 inner diameters of user-defined glass syringe barrel 
- Linear force output: Full stroke > 20 N 
- Memory functon: Select resume operaton or remain stopped when power returns after an interruption 
- Signal output: Start/Stop output, cw/ccw output (Open Collector) 
- Calibration: Acquire accurate volume through calibration 
- Fast forward & fast reverse: Infusion or filling at the max. Speed

 

Parameters:

Controller
(Product code)

Drive Unit
(Product Code)

Syringe (μl)

Syringe ID (mm)

Flow Rate (nl/min-μl/min)

TR-TC-2A (0503111)

L0701-2A (0503011)

5

0.35

0.764 - 7.64

10

0.50

1.559 - 15.59

25

0.80

3.991 - 39.91

50

1.10

7.546 - 75.46

100

1.60

15.96 - 159.6

250

2.30

32.99 - 329.9

500

3.25

65.87 - 658.7

1000

4.61

132.5 - 1325

 

 


0