TR-TCDE-02 Microwave Digestion & Extraction System


COMPANY : Tryte Technology (H.K.) Limited
ADD : UNIT 04, 7/F, BRIGHT WAY TOWER, NO. 33 MONG KOK ROAD, KOWLOON, HONGKONG.
TEL:00852-2389298
FAX: 00852-35902333
CELL:0086-15367067787(Robin)
SITE : www.trytetc.com
SKYPE : live:myformat666
EMAIL : sale@trytetc.com
more>>>

  • Name: TR-TCDE-02 Microwave Digestion & Extraction System
  • Model : TR-TCDE-02
  • Erp code: 9000000436
  • | Share

TR-TCDE-02.jpg


Parameter:

  • Microwave in-feed mode: real non-burst variable frequency microwave power adjusts;

  • Dual-CPU monitoring: dual-CPU interactive monitoring mode, control temperature and pressure automatically and accurately, auto adjust microwave input power. Unique pressure changing rate inhibit function, avoid sample pressure undulate too large;

  • Microwave power and frequency: adjustable in 1200W (50-100%P), frequency: 2450MHz;

  • Temperature and pressure control: maximum working temperature: (precision:±1℃); non-contact pressure control range: 0.1-5MPa (precision:±0.01MPa); instrument use the pressure auto control mode which is the safest one;

  • Operation program: once 9 operation programs can be set, modified, saved and called. Each program (method) has 9 operation steps (phases), time of each step can be set from 1 to 9999s, auto complete and switch between steps; zero and full-range adjustment can auto completed, ensure that the pressure is invariable;

  • Microwave “Shock” function: a unique pause/start microwave “shock” design, user can turn on the light to check or continue running. When the pressure rising rate is too large(≥0.2MPa/s), microwave will cut off by instrument, after pressure is down, microwave in-feed automatically, which greatly improve the safety and convenience of the operation;

  • Multiple safety measures, 7 safety measures and their explanation are as the following:

    • High pressure exterior vessel: PSF exterior vessel with PPS liner, maximum pressure endurance is 6MPa (900 psi);

    • Overheating protection: when the crate or the external vessel is overheated, instrument will warn and suspend microwave radiation;

    • Abnormal noise detecting: when there is abnormal noise detecting in the furnace chamber, instrument will warn and cut off microwave automatically;

    • Overpressure warning: pressure auto matching and control, pressure rising rate auto restrictions, overpressure auto warning;

    • Forced suspend: once a safety problem occurs, the user can force the instrument to suspend microwave production by ‘emergency stop button’ or ‘remote control’;

    • Dual pressure reduction by air bleed hole and bursting film: when the gas pressure in the digestion vessel is too large, gas will leak from the air bleed hole; when the pressure is larger than the limit value and the hole can’t leak the air in time, the skirt border of the sealing bowl will broken, then leak gas and reduce pressure

    • A protective cover: a high strength protective cover made by PC is fitted before the furnace door, which ensures the absolutely safety of the operator;

  • Intelligent design: unique abnormal noise detecting system, wireless remote control, resistant microwave and visible light interference, abnormal information auto sense, diagnose and display, temperature overheating protection;

  • Simple operation: fool-operational menu interface; convenient to set work parameter; error message real-time diagnose and prompt, operation is simple and clear; needs no auxiliary means to open or close digestion vessel;

  • Standard accessory: 12 sets of high pressure inner vessel, 6 sets of exterior vessel; 10 sealing bowls; 20 blocks of elastomer; a 12-holes sample-cup holder; a cooling machine;

  • Working condition and others:

  • Power Source: A.C. 220V±10%, 50Hz

  • Input power: 1360W

  • Size: furnace chamber volume, 34L; exterior size, 510mm*510mm*420mm

  • Weight: 30Kg

 

Description:

In the modern chemical analysis, the analysis of elements which are closely related to human health, environment protection, material composition, mineral content and food safety attract more and more concern. As is known to all, the abio-analysis includes sample pretreatment and analyze by instruments. Modern instruments (as AFS, AAs, ICP-AES, ICP-MS etc.) and technology have developed rapidly. The measurement can be completed within several minutes, even seconds while the sensitivity and precision are satisfying. Therefore, the technology and methods for sample pretreatment are the determinants in the speed and quality of analysis. However, the present sample pretreatment methods like acidolysis, alkaline bath and dry process incineration which are usually adopted by laboratory have various disadvantages, for example, long-last period, huge energy consumption, large amount of reagent needed, sample cross contamination and target element (esp. As, Hg, Pb, Se, etc) losing during the pretreatment. Scientists have been keeping trying to discover methods to overcome these shortages and finally, in 1986, put forward the idea of using microwave into the pretreatment process of sample. Once the idea was raised, related high-pressure and normal atmosphere methods, technology and instruments of microwave digestion/extraction were widely accepted and developed tremendously.

With more than ten years’ development, our company have developed and produced a series of microwave digestion/extraction which were approved by our clients. In order to meet the market and clients’ requirement, we produced a upgrading instrument – XT-9900A Intelligent Microwave digestion/Extraction which was designed based on the original XT-9900 Intelligent Microwave digestion/Extraction. XT-9900A was developed according to our study during these years. It kept the advantages of XT-9900 and improved on the appearance, interface design and vessel’s material.
 

 Capital Feature:

  • Power control: real function of ‘non-burst variable frequency microwave power adjusts’.

  • High intelligence: dual-CPU control, intelligent pressure and temperature control, good accuracy and precision.

  • Program control: 9 operation programs that parameters (pressure, time and power) are freely set. Instrument can auto variable frequency microwave input by the set parameters, which achieve auto pressure and temperature control.

  • Multiple safety measures: innovative pressure surge program auto recognition and protection (‘Shock’); abnormal noise detecting protection; oven shell overheating protection; program running pause/start; system failure self-check and warning; power-off by hand, remote control or emergency stop switch; dual pressure reduction by inner vessel’s air bleed hole and bursting film; high strength protective cover.

  • Easy to operate: instrument self-check begins after being electrified; auto regulate zero and full of pressure, ringing prompt; when abnormal noise is made in the furnace chamber, instrument stop working automatically; once unusual appears, instrument will diagnose and display error message.

  • Brand-new working interface: menu type interface, operating by hand or remote control, sound prompt, auto prohibit unsuitable operation, simple and easy to learn.


Parameter:

  • Microwave in-feed mode: real non-burst variable frequency microwave power adjusts;

  • Dual-CPU monitoring: dual-CPU interactive monitoring mode, control temperature and pressure automatically and accurately, auto adjust microwave input power. Unique pressure changing rate inhibit function, avoid sample pressure undulate too large;

  • Microwave power and frequency: adjustable in 1200W (50-100%P), frequency: 2450MHz;

  • Temperature and pressure control: maximum working temperature: (precision:±1℃); non-contact pressure control range: 0.1-5MPa (precision:±0.01MPa); instrument use the pressure auto control mode which is the safest one;

  • Operation program: once 9 operation programs can be set, modified, saved and called. Each program (method) has 9 operation steps (phases), time of each step can be set from 1 to 9999s, auto complete and switch between steps; zero and full-range adjustment can auto completed, ensure that the pressure is invariable;

  • Microwave “Shock” function: a unique pause/start microwave “shock” design, user can turn on the light to check or continue running. When the pressure rising rate is too large(≥0.2MPa/s), microwave will cut off by instrument, after pressure is down, microwave in-feed automatically, which greatly improve the safety and convenience of the operation;

  • Multiple safety measures, 7 safety measures and their explanation are as the following:

    • High pressure exterior vessel: PSF exterior vessel with PPS liner, maximum pressure endurance is 6MPa (900 psi);

    • Overheating protection: when the crate or the external vessel is overheated, instrument will warn and suspend microwave radiation;

    • Abnormal noise detecting: when there is abnormal noise detecting in the furnace chamber, instrument will warn and cut off microwave automatically;

    • Overpressure warning: pressure auto matching and control, pressure rising rate auto restrictions, overpressure auto warning;

    • Forced suspend: once a safety problem occurs, the user can force the instrument to suspend microwave production by ‘emergency stop button’ or ‘remote control’;

    • Dual pressure reduction by air bleed hole and bursting film: when the gas pressure in the digestion vessel is too large, gas will leak from the air bleed hole; when the pressure is larger than the limit value and the hole can’t leak the air in time, the skirt border of the sealing bowl will broken, then leak gas and reduce pressure

    • A protective cover: a high strength protective cover made by PC is fitted before the furnace door, which ensures the absolutely safety of the operator;

  • Intelligent design: unique abnormal noise detecting system, wireless remote control, resistant microwave and visible light interference, abnormal information auto sense, diagnose and display, temperature overheating protection;

  • Simple operation: fool-operational menu interface; convenient to set work parameter; error message real-time diagnose and prompt, operation is simple and clear; needs no auxiliary means to open or close digestion vessel;

  • Standard accessory: 12 sets of high pressure inner vessel, 6 sets of exterior vessel; 10 sealing bowls; 20 blocks of elastomer; a 12-holes sample-cup holder; a cooling machine;

  • Working condition and others:

  • Power Source: A.C. 220V±10%, 50Hz

  • Input power: 1360W

  • Size: furnace chamber volume, 34L; exterior size, 510mm*510mm*420mm

  • Weight: 30Kg


0